Air Source Heat Pump With Underfloor Heating
Air Source Heat Pump With Underfloor Heating
Product Details

Product name

Air source heat pump with underfloor heating

Details

1. Certification: ISO9001, CE, erP Energy Label

2.ASHP Heating Capacity: 10kw heat pump water heater

3. Ambient Temp of Using: Minus 25C, highest 60C hot Water Output

4.  Best Selling Market: Central, North & East Europe, North Europe, North America.

5.Copland EVI compressor.

Packaging Details

Plywood. suitable for export .

If container is too tigher,we will use pe film for packing or pack it according to customers special request.

Market

New Energy Heat Pump is well sold in Europe and North America Market, including US, Canada, Germany, Sweden, Poland, Ukraine, Russia, Finland, Czech, Slovak, Slovenia, etc.

NEW ENERGY HEAT PUMP is the official heat pump supplier for 18th Indonesia Asian Games and for China North & South Pole Expedition Team.

Trust that we will offer best quality and service to you.

Product pictures

Model

SHP08 INV

SHP11 INV

SHP16 INV

SHP17 INV

SHP23 INV

Heating   capacity                     kW

7.8

10.6

15.5

16.8

22.8

Power input                                kW

1.7

2.5

3.5

3.97

5.56

COP

4.59

4.24

4.43

4.23

4.1

Cooling capacity                       kW

8.4

10.81

15.2

15.5

23.1

Power input                                kW

2.25

2.6

3.98

3.90

5.82

EER

3.73

4.16

3.82

3.98

3.97

Power supply

230V/1Ph/50Hz

400V/3Ph/50Hz

Maximum water temperature    

60

Working outside temperature  

-20~43

Refrigerant

R410A

DC inverter compressor

Twin rotary

Evaporator

Fin-tube   heat exchanger with hydrophilic coating

Condenser

Plate heat exchanger

Dimensions (W*D*H)                mm

1115*425*710

1115*425*960

1115*425*1280

1115*425*1280

1115*425*1462

Noise Level at 1 meter          dB(A)

54

56

57

58

60

Net/gross weight                         kg

90/100

105/115

140/150

140/150

185/195

Test conditions:

Heating: outside temperature (DB/WB) =7/6, water inlet/outlet=30/35

Cooling: outside temperature (DB/WB) =35/24, water inlet/outlet=23/18