Air To Air Heat Pump Systems
Air To Air Heat Pump Systems
Product Details

Product name

Air to air heat pump systems

Brief introduction 

Air to air heat pump systems works with fan coil, radianl floor heating and domcslic hot water supply system. It could take advantage and efficiency of heat pump at the best performance, also reach

multi-usage, safety, energy saving and comfortable effect.

Product features

1. Air-conditioning cooling in summer

2. Heating in winter

3. Domestic hot water provided

4. The air to air heat pump system can work at -25DegC ambient temperature;

5. High quality components such as COPELAND R407C EVI compressor, plate heat exchangers for main circuit and assistant circuit, WILO circulation pump, water flow switch etc.

6. Optimized defrosting system

7. Fast drainage design for condensing water from defrosting.

8. Bottom plate heater under evaporator;

9. Aviation plug to simplify the installation and avoid  mistakes  on wiring;

10. Every component is easily accessible for maintenance.

11. Low noise by low speed fans , complete isolation of compressor noise and noise absorption material.

12. Comsiderate design to keep compressor warm including the crankcase heater and the closed space to avoid heat loss.

13. Air vent on top of indoor unit .

14. Out door unit designed for anti-snow;


Model

SHP08 EVI

SHP11 EVI

SHP14 EVI

SHP16 EVI

SHP20 EVI

SHP28 EVI

Heating capacity                  kW

8.0

11.0

14.0

16.0

20.0

28.0

Power input                          kW

1.97

2.71

3.4

3.91

4.9

7.02

COP

4.06

4.06

4.12

4.09

4.08

3.99

Cooling capacity                   kW

6.0

8.25

10.5

12.0

15.0

21.0

Power input                          kW

2.48

3.4

4.25

4.89

6.16

8.65

EER

2.42

2.43

2.47

2.45

2.44

2.43

Power supply

230V/1Ph/50Hz

400V/3Ph/50Hz

Maximum water

temperature                          

60

Working outside

temperature                         

-25~43

Refrigerant

R407C

DC Inverter compressor

EVI scroll

Evaporator

Fin-tube heat   exchanger with hydrophilic coating

Condenser

Plate heat exchanger

Dimensions   (W*D*H)      mm

1090*425*875

1090*425*960

1090*425*1260

1090*425*1260

1090*425*1430

1090*425*1430

Noise Level at 1 meter    dB(A)

54

57

57

58

60

61

Net/gross  weight                  kg

95/105

105/115

140/150

146/156

158/168

190/200

Test conditions:

Heating: outside temperature (DB/WB) =7/6, water inlet/outlet temperature =30/35

Cooling: outside temperature (DB/WB) =35/24℃, water inlet/outlet temperature =12/7


Feedback