Monoblock Air Source Heat Pump with EVI Heating Technology
Product Details

EVI Heating Technology inside 

EVI Air to Water Heat Pumps have much better heating performance compared with normal heat pumps, the lower the outside temperature is the more obvious the advantage will be.  Thanks to the innovative heating technologies,  this heat pump works well even when outside temperature is as low as minus 20℃,  up to 30~40%  extra heating capacity  is obtained compared with normal heat pumps.  Except heating function, cooling function is available in summer and hot water function is available all year round, this means you can have a completed solution for your house with one unit.

Benefits for You
Completed solution for heating, cooling and hot water. 
Compact design, integrated with all essential parts in one block.
Excellent heating performance at low outside temperature, even as low as -20℃ .  
High efficiency due to the optimally designed heat exchanger with big heat exchange area.
Top quality and reliability, all important components from leading brands.
Quite operation, space saving, easy installation.



Model

SHP08 EVI

SHP11 EVI

SHP14 EVI

SHP16 EVI

SHP20 EVI

SHP28 EVI

Heating capacity                  kW

8.0

11.0

14.0

16.0

20.0

28.0

Power input                          kW

1.97

2.71

3.4

3.91

4.9

7.02

COP

4.06

4.06

4.12

4.09

4.08

3.99

Cooling capacity                   kW

6.0

8.25

10.5

12.0

15.0

21.0

Power input                          kW

2.48

3.4

4.25

4.89

6.16

8.65

EER

2.42

2.43

2.47

2.45

2.44

2.43

Power supply

230V/1Ph/50Hz

400V/3Ph/50Hz

Maximum water

temperature                          

60

Working outside

temperature                         

-25~43

Refrigerant

R407C

DC Inverter compressor

EVI scroll

Evaporator

Fin-tube heat   exchanger with hydrophilic coating

Condenser

Plate heat exchanger

Dimensions   (W*D*H)      mm

1090*425*875

1090*425*960

1090*425*1260

1090*425*1260

1090*425*1430

1090*425*1430

Noise Level at 1 meter    dB(A)

54

57

57

58

60

61

Net/gross  weight                  kg

95/105

105/115

140/150

146/156

158/168

190/200

Test conditions:

Heating: outside temperature (DB/WB) =7/6, water inlet/outlet temperature =30/35

Cooling: outside temperature (DB/WB) =35/24℃, water inlet/outlet temperature =12/7